RoofAquaGuard MT
Material Safety Data Sheet (MSDS)
| (278KB) |
Material Safety Data Sheet (MSDS)
PRINTABLE MSDS SHEET
1. Product identification, composition and use
| Product Name: | RoofAquaGuard MT |
| Composition: | RoofAquaGuard MT is manufactured with a Polyester carrier and SBS modified bitumen. |
| Product Use: | Intended for use as a roofing underlayment |
| Manufacturer: | Lemminkainen Rakennustuotteet OY Sammonmaki, PL 10 Puusepantie 11 04361 Tuusula Finland |
| Telephone: | (358) 9 870 441 |
| Fax: | (358) 98251 070 |
2. Hazardous Ingredients/Warnings
The product is chemically inactive and is biologically inert. It is not a skin irritant.
RoofAquaGuard MT underlayment raw materials and additives contain no asbestos or asphalt products. This declaration is based on individual approvals obtained by the suppliers of Lemminkainen Rakennustuotteet OY raw materials and ingredients.
To avoid danger or suffocation, the product should be kept away from babies and children. This product is not considered dangerous to the environment.
3. Fire Hazard
This product burns, but is not classified as flammable. Flash point is approximately 350° Celsius (662°F).
The final products at complete combustion are carbon dioxide and water. At incomplete combustion with reduced oxygen supply, carbon monoxide, which is highly toxic, may form.
As for many other compounds, like wood, paper and other products from oil other decomposition products like various hydrocarbons, acids and aldehydes may also form, but only in very small quantities.
4. Fire Fighting
Water in a spread jet, dry chemical, foam and carbon dioxide can be used.
5. Handling
The product is stable under normal conditions of use, storage and transportation. For safe installation, it is
recommended to follow installation instructions given by the manufacturer/seller.
6. Waste Handling
The product can be used as landfill, or incinerated, as required.
| DISCLAIMER THIS INFORMATION IS FURNISHED WITHOUT WARRANTY EXPRESSED OR IMPLIED, EXCEPT THAT IT IS ACCURATE TO THE BEST KNOWLEDGE OF LEMMINKAINEN RAKENNUSTUOTTEET OY AND ASSUMES NO LEGAL RESPONSIBILITY FOR USE OR RELIANCE ON THIS DATA |
Specification Sheet
1. Classification
Roof covering and roof deck construction-Underlayment. Can be used on steep sloped roofs beneath
composite, metal, clay, concrete, slate, wood and other roofing
materials.
2. Product Name
RoofAquaGuard MT High Performance Roofing Underlayment
3. Manufacturer
Lemminkainen Rakennustuotteet OY
Sammonmaki, PL 10
Puusepantie 11
04361, Tuusula
Finland
www.roofaquaguard.com
4. Product Description
RoofAquaGuard MT is manufactured with a polyester carrier and SBS
modified bitumen. RoofAquaGuard MT measures 40 in. wide and
comes in 60 ft. rolls weighing 41 lbs. per roll.
The average coverage per roll is 2 squares.
RoofAquaGuard MT is green in color which helps reduce heat loads on attic structures.
5. Approvals
ICC-ESR #3022
Miami Dade NOA #09-0527.02
Florida Building Code approval: FL #10657
CAN/CSA: A220
6. Testing
Passed ICC-ES AC 48 and ASTM D1970
Passed Miami Dade
Passed Florida Building Commission
Passed CAN/CSA
7. Installation
Always start from the lowest point on roof deck. The membrane should be
unrolled, exposed to sunlight and allowed to relax before installation. Align
the membrane on the lower edge of roof. Pull back the release film and
align the membrane on the lower edge of roof. Pull the release film to peel
back and apply membrane. Roll lower edges and seams with a hand roller.
Use flat broom or squeegee to help lay flat and adhere the field of the
underlayment. Where nailing is required for steep 9:12 pitch and above,
slope applications, back-nail and cover nails by overlapping with the next
sheet. Valley and ridge applications: peel back the release film, center the
sheet over the valley or ridge and press firmly into place. Always start from
lowest point on valley applications. End laps must be at least 6 inches and
side laps must be at least 3 inches. For best adhesion, apply in minimum
45°F or higher. Store rolls at temperatures between 55°F and 95°F.
It is recommended that a roof jack, with planks, toe boards, or a strong
platform be secured to the underlying roofing deck to prevent slippage
of stored materials on steep sloped roofs (greater than 4:12 pitch). See
OSHA regulations (Standard 29 CFR), fall protection systems criteria and
practices - 1926.502. Installing final roofing within 6 months from initial
underlayment application is recommended.
8. Technical Services
RoofAquaGuard MT provides a 35 year limited material warranty. For warranty and technical information, go to www.roofaquaguard.com.
9. Maintenance
None when installed in accordance with manufacturer's recommendations.