RoofAquaGuard BREA

Technical Data

Breathable Roofing Underlayment – Specification Data

Checked Characteristics NORM (Relavant Standard) Value Unit of measure Converted Unit of measure
Roll size   59" x 164' 806 sf/roll  
No. of layers   4    
Up Side   PP non woven    
Inside  

Breathable FILM

Reinforcement mesh

   
Down Side   PP non woven    
Mass Per Unit Area EN 13859-1 175± 5% g/m2 28.7lb/roll  
Thickness EN 1849-2
(TAS 104-95)
0.8 ± 5% mm 30 mil  

Tensile Strength

(longitudinal)

EN 123311-1
(AC 38)
MD: 310±15%  CD:340±15% 460N/5cm MD: 52 lbf/in 

Tensile Strength

(transverse)

EN 123311-1
(AC 38)
MD: 310±15%  CD:340±15% 400N/5cm MD: 45 lbf/in 

Elongation at Break

wet strength longitud.

    20% 20%

Nail Tearing

(longitudinal)

EN 12310-1 MD: 190±15%  CD:200±15% 350 N 39 lbf

Nail Tearing

(transverse)

EN 12310-1 MD: 190±15%  CD:200±15% 375 N 42 lbf
Water Column   >3000mm   H2O >118”
UV Resistance (AC 38) 4 months    
Conforms to AC 188      
Water Vapor
Transmission Property
EN 13859-1 (AC38) WDD=810 ± 15%    23°C  50-93% RH 1034g/m2-24h *see chart
Water Vapour Resistance BS 3177   0.18MNs/g  
Resistance to Temperature EN 13859-1
(AC 38)
-40°C to 80°C   -40°F to 176°F

* chart

Test Result Summary Metric Units Imperial Units
Water Vapor Transmission 43 g/hr.m² 62 grns/hr.ft²
1034 g/day.m² 1479 grns/day.ft²
Water Vapor Permeance 8333 ng/Pa.s.m² 146 perms
Water Vapor Permeability 4 ng/Pa.s.m 9530  Perm inch
   

^ top

 

Roof Aqua Guard North America Marketing and Sales: Nemco Industries Inc

Member of the following industry associations: